The further development of our special flanges is combined in the VP flange, which is equipped with a corrosion-free, fiber-reinforced plastic backing flange drilled to DIN EN 1092 PN 10. Slotted holes in the collar allow easier assembly and alignment of the flange connection. The spring effect of the flange integrated into the design, which ensures permanent bolt pretensioning, is a particular highlight. Its low weight in particular reduces installation work and project costs.
Technical data
Complete data sheet
Tender text
PE100 fittings with tensile plug-in connection REINOGRIP system Generalpreliminary remarks The fittings to be offered must be made of material in accordance with the PE100+ Association and comply with DIN EN 12201 in terms of dimensions, tolerances and quality requirements. Proof of production on the basis of a quality assurance system in accordance with DIN EN ISO 9001 must be provided. A certificate in accordance with DIN EN 10204 must be provided by the manufacturer for all molded parts. Alternatively, the body of the molded part must be manufactured from a single piece of homogeneous semi-finished material using the injection molding process, even for more complex structures, in order to ensure the required reinforcement and thus high stability of the molded part. Semi-finished products made from winding rod or other subsequently applied reinforcements are not permitted. The tension-resistant plug connections must have grip elements, each with at least 5 grip teeth made of high-strength plastic, which are arranged on spring-loaded holders.
An elastomer ring must ensure that the grip is self-activating.
An elastomer profile ring must be fitted at the inlet of the plug connection as a wiper to prevent the ingress of dirt.
A pressure-tight System 3S lip seal in drinking water quality must be installed as a media seal.
Spigot ends on the fittings must be long in order to be able to carry out both plugging and HE butt welding or HW welding.
Flange connection dimensions must be designed in accordance with DIN EN 1092–1.
Depending on the type of mating flange, flange connections must be designed either as a loose flange connection or as a fixed flange connection (with the same nominal width). The backing flanges must be made of corrosion-free, fiber-reinforced plastic. The collar and flange must interlock positively at their connecting surfaces and the flange must also support the collar from the outside to counteract deformation.
This ensures that the flange connection can withstand full pressure in accordance with the pipe dimensions.
The backing flange is captively connected to the welding neck.
The use of a profile seal for flat-sealing collars is recommended if no other seal is available in the system.
Read more
- PE100 double coupler, pull-resistant according to DVGW, pressure class-compatible, with EPDM lip seal and dirt-repellent profile ring, for PE100 pipe of the size
DN/OD [d1] …
SDR …
Operating pressure … bar
- PE100 bend 1 x d, with push-fit coupling on both sides, pull-resistant according to DVGW, pressure class-compatible, with EPDM lip seal and dirt-repellent profile ring, for PE100 pipe of the size
DN/OD [d1] …
SDR …
… degrees
Operating pressure … bar
- PE100 bend 1 x d, with push-fit coupler on one side, pull-resistant according to DVGW, pressure class-compatible, with EPDM lip seal and dirt-repellent profile ring, for PE100 pipe of the size
DN/OD [d1] …
SDR …
… degrees
Operating pressure … bar
- PE100 tee, with all-round push-fit coupling, pull-resistant according to DVGW, pressure class-compatible, with EPDM lip seal and dirt-repellent profile ring, for PE100 pipe of the size
DN/OD1 [d1] …
DN/OD2 [d2] …
SDR …
Operating pressure … bar
- PE100 tee with HP flange outlet, with push-fit couplers in the run pipe, pull-resistant according to DVGW, pressure class-compatible, with EPDM lip seal and dirt-repellent profile ring, for PE100 pipe of the size
DN/OD [d1] …
SDR …
DN …
PN … drilled
Operating pressure … bar
- PE100 concentric reducer, with push-fit coupling on both sides, pull-resistant according to DVGW, pressure class-compatible, with EPDM lip seal and dirt-repellent profile ring, for PE100 pipe of the size
DN/OD1 [d1] …
DN/OD2 [d2] …
SDR …
Operating pressure … bar
Read more
7. PE100 concentric reducer, with coupler on one side, pull-resistant according to DVGW, pressure class-compatible, with EPDM lip seal and dirt-repellent profile ring, second side long for HW welding , for PE100 pipe of the sizeDN/OD8 [d1] …
DN/OD9 [d2] …
SDR …
Operating pressure … bar
8. PE100 repair coupler, pull-resistant according to DVGW, pressure class-compatible, with EPDM lip seal and bolt preload for secure fixing, for pipes of the size
Material 1: □ PE100 □ PVC □ PP
DN/OD1 [d1] …
SDR …
Material 2: □ PE100 □ PVC □ PP
DN/OD1 [d1] …
SDR …
Operating pressure … bar
9. PE100 push-fit socket, consisting of push-fit coupler, pull-resistant according to DVGW, pressure class-compatible, with EPDM lip seal and dirt-repellent profile ring, and HP flange for PE100 pipe of the size
DN/OD1 [d1] …
SDR …
DN …
PN …
Operating pressure … bar
10. PE100 telescope repair set, with push-fit coupling on both sides, pull-resistant according to DVGW, pressure class-compatible, with EPDM lip seal and dirt-repellent profile ring, for pipes of the size
Material 1: □ PE100 □ PVC □ PP
DN/OD1 [d1] …
SDR …
Material 2: □ PE100 □ PVC □ PP
DN/OD1 [d1] …
SDR …
Operating pressure … bar
11. PE100 duckfoot bend for connection to hydrant, reinforced design, with push-fit coupler, pull-resistant according to DVGW, pressure class-compatible, with EPDM lip seal and dirt-repellent profile ring, with adapter for hydrants with bayonet spigot, for pipes of the size
DN/OD1 [d1] …
SDR …
Operating pressure … bar
12. PE100 hydrant end piece for service line connection, reinforced design, with push-fit coupler, pull-resistant according to DVGW, pressure class-compatible, with EPDM lip seal and dirt-repellent profile ring, with adapter for hydrants with bayonet spigot, for pipes of the size
DN/OD1 [d1] …
SDR …
DN/OD3 [d3] …
SDR …
Operating pressure … bar
13. PE100 tee for connection to hydrant, reinforced design, with push-fit coupler on both sides, pull-resistant according to DVGW, pressure class-compatible, with EPDM lip seal and dirt-repellent profile ring, with adapter for hydrants with bayonet spigot, for pipes of the size
DN/OD1 [d1] …
SDR …
Operating pressure … bar
14. PE100 cross for connection to hydrant, reinforced design, with all-round push-fit coupling„ pull-resistant according to DVGW, pressure class-compatible, with EPDM lip seal and dirt-repellent profile ring, with adapter for hydrants with bayonet spigot, for pipes of the size
DN/OD1 [d1] …
SDR …
Operating pressure … bar
Read more
-
- PE100 X‑cross for connection to hydrant, reinforced design, with all-round push-fit coupling„ pull-resistant according to DVGW, pressure class-compatible, with EPDM lip seal and dirt-repellent profile ring, with adapter for hydrants with bayonet spigot, for pipes of the size
DN/OD1 [d1] …
SDR …
Operating pressure … bar
- PE100 duckfoot bend for connection to hydrant, reinforced design, with push-fit coupler, pull-resistant according to DVGW, pressure class-compatible, with EPDM lip seal and dirt-repellent profile ring, with special flange connection (VP flange) of the same nominal diameter with fibre-reinforced backing flange at outlet, drilled according to DIN EN 1092–1, with spring effect for continuous bolt preload, for pipes of the size
DN/OD1 [d1] …
SDR …
DN …
Operating pressure … bar
- PE100 hydrant end piece for service line connection, reinforced design,with push-fit coupler, pull-resistant according to DVGW, pressure class-compatible, with EPDM lip seal and dirt-repellent profile ring, with special flange connection (VP flange) of the same nominal diameter with a fibre-reinforced backing flange at the outlet, drilled according to DIN EN 1092–1, with spring effect for continuous bolt preload, for pipes of the sizes
DN/OD1 [d1] …
SDR …
DN …
DN/OD3 [d3] …
SDR …
Operating pressure … bar
- PE100 tee for connection to hydrant, reinforced design, with push-fit coupler on both sides, pull-resistant according to DVGW, pressure class-compatible, with EPDM lip seal and dirt-repellent profile ring, with special flange connection (VP flange) of the same nominal diameter with fibre-reinforced backing flange at outlet, drilled according to DIN EN 1092–1, with spring effect for continuous bolt preload, for pipes of the sizes
DN/OD1 [d1] …
SDR …
DN …
Operating pressure … bar
- PE100 cross for connection to hydrant, reinforced design, with all-round push-fit coupling, pull-resistant according to DVGW, pressure class-compatible, with EPDM lip seal and dirt-repellent profile ring, with special flange connection (VP flange) of the same nominal diameter with fibre-reinforced backing flange at outlet, drilled according to DIN EN 1092–1, with spring effect for continuous bolt preload, for pipes of the sizes
DN/OD1 [d1] …
SDR …
DN …
Operating pressure … bar
- PE100 X‑cross for connection to hydrant, reinforced design, with all-round push-fit coupling, pull-resistant according to DVGW, pressure class-compatible, with EPDM lip seal and dirt-repellent profile ring, with special flange connection (VP flange) of the same nominal diameter with fibre-reinforced backing flange at outlet, drilled according to DIN EN 1092–1, with spring effect for continuous bolt preload, for pipes of the sizes
DN/OD1 [d1] …
SDR …
DN …
Operating pressure … bar
Proof of delivery:
Reinert-Ritz GmbH
Ernst-Heinkel-Straße 2
48531 Nordhorn
Tel.: +49 5921 8347–0
Fax: +49 5921 8347–25
www.reinert-ritz.de
Email: contact@reinert-ritz.com-
Downloads
REINOGRIP double plug-in coupling data sheet
Installation instructions
REINOGRIP brochure
REINOGRIP product catalog
No root ingrowth with REINOGRIP